Radon mitigation installation involves four types of main process and anyone can be chosen to stop the abundant of ran in any closed place. Processes are crawl space depressurization, drain tile depressurization, sub slab depressurization and block wall depressurization. To install a mitigation system first step is visual inspection of place and after survey we will suggest you the best system for you place and once the deal is done, the whole process is done within a week. We are providing our facilities in local communities, hospitals and old-fashioned homes etc. Radon mitigation system is installed considering the condition and location of place.

The radon mitigation system basically consists of three processes; drilling, fan installment and piping assembly. Drilling is the fundamental process involved in mitigation process. This process involves the drilling hole in the basement to access the ground. Drilling is done with mechanical drill bits and it is the time taking process. After drilling the indoor piping assembly is fitted. This assembly involves the pipes and elbows to avoid any king of the additional damage to your house. The assembly is installed at appropriate point in the house and once the indoor assembly is installed, next step is the installation of the fan is the outdoor assembly. In piping assembly, the pipes of different diameters are used. But the whole assembly is completed with the same diameter of the pipe. The fan is installed just after the piping moved outside. Purpose of fan is to force the trapped gas inside ground to move upward. Once the fan is installed the outer piping assembly is inserted vertically up.

Radon mitigation system is the one-time investment to ensure the long-term life span of the building. The whole process takes maximum a week to complete If the mitigator system is not installed it can be ultimately dangerous to human because radon if responsible for lung cancer.  After complete installation of the radon system, the system testing is done timely to ensure the proper working of mitigator. There are two types of tests: For a short-term test, it is mandatory to close doors and windows as much as possible and do not use the fan as this will cause the transfer of indoor air to outdoor air and proper results may not be generated. For accuracy of short-term test, it is necessary to know the exact quantity of the radon present in a place. Short-term devices that can be helpful for conducting the test are charcoal patches, electret ion compartments and Alpha-track system. Radon levels oscillate timely, accurate readings can be obtain with the help of long-term test. These tests monitor radon levels for more than 90 days. electret ion chamber detectors and Alpha-track gauges are frequently used to perform long-term tests. Test kit is placed in the basement or in the lowest level of the home. When the duration of test is complete, the sample are packed and the specimens are sent to the lab for analysis and after analysis results are collected and the level of radon is obtained.